Building height maximum 30 mm

Send link to this page Your Nexans contact on this page

If you have the possibility to elevate the floor 30 mm or more using ordinary heating cables like TXLP/TKXP probably is your best choice. Keep in mind the power per meter with regards to center – center distance and even heat distribution.

TXLP/2R recommended
Recommended product for this application is TXLP/2R, preferably 10 W/m products with hidden splice. The cable is installed on existing floor and embedded in mortar/screed. After hardening vinyl or tiles are installed on the top. If you are installing a wooden floor please follow the guidelines of the actual wooden floor with respect to the power per m². Never install more than 80 W/m² in wooden floors unless uniquely specified by a manufacturer.

Floor construction 

  1. Cable installed behind the WC to dry condense water.
  2. Gully
  3. Distance to gully should minimum be 100 mm.
  4. Cold lead (Should be place in a “dry” zone of the floor)

 