Nexans heating cables in stairs should be laid lengthways on the steps so that they lie only on the horizontal surfaces. The cables are covered with a 30 - 50 mm screed or paving slabs embedded in mortar.

StairsUse DEFROST SNOW with 4-5 cable runs in each step, or TXLP series resistance heating cable, which is well suited for medium or large installations.

 

Limitations
With sand/slabs: Max. 30 W/m (9 W/ft) of cable*
Asphalt: Max. 30 W/m (9 W/ft) of cable
Concrete: Max. 35 W/m (10 W/ft) of cable

Note: When using long cables, potential capacitance problems may occur.
* If unsure about the thermal conductivity of the sand, please limit the power to 25 W/m (7,6 W/ft).

 

Installation
The heating cables shall be installed with even spacing. Avoid concentration of heating cables that will result in uneven cable and surface temperatures, and might cause overheating and breakdowns in the worst case. Always measure insulation and conductor resistance before and immediately after covering the cables. Be aware that the insulation resistance tends to become lower at high temperature, e.g. when measuring the cable in warm asphalt.


Nexans Products
Product Name   PDF file
Defrost snow 230V 28W/m
Snow melting/Snow melting
Defrost snow används för att smälta snö och is på gator, infarter, planer, entréer, ramper etc.
 
TXLP/2R snow melting
Snow melting/Snow melting
Twin conductor heating cable units for direct heating
 

 TOP
Nexans © copyright 2001 - 2012   Legal Notice | Contact Us | Site Map