Send link to this page print Your Nexans contact on this page
FQQ 300/500 V International Designation  S05Z1Z1-R
The cable may be used for permanent installation on ladders, directly in walls, concrete, in conduits or ducts. For use indoors and outdoors but not in ground or water. The cable have protection against exposure of UV-light.
Lifemark
Standards
National  SS 424 02 19-5
Description

FQQ is a halogen free, HFFR-insulated and HFFR-sheathed house wiring cable with circular, stranded copper conductors. The cable is designed according to SS 424 02 19-5. The conductors have resistance and number of wires according to IEC 60228 class 2. The cores are identified by colours according to HD 308. Cables with 7 core are numbercoded, (1-6 and yellow/green).The cable has an extruded filler. The sheath is marked. type/manufacturer/year+month/metre marking. FQQ meets the requirements for flammability according to IEC 60332-1 (F2 and F3) and have protection against exposure of UV-light according to HD 626 S1 part 2.5.1. The conductor insulation shall be protected against UV light that can occur for example in light fixtures and light signs. The cable is certified by SEMKO.

 

Lifemark(TM) recycling marking

The external surface of the outer sheath is embossed with a text which specifies all components in the polymers and prepares the cable for future recycling.

Certification

Certifeid by SEMKO.

Quality and environmental management system

ISO 9001 and ISO 14001.


 TOP
Characteristics
Construction characteristics
Conductor material Copper  
Conductor shape Circular  
Conductor flexibility Stranded class 2  
Insulation HFFR  
Outer sheath HFFR (polyolefin)  
Colour White  
Halogen free Yes  
Electrical characteristics
Rated Voltage Uo/U (Um) 300 / 500 V  
Usage characteristics
Minimum installation temperature -10°C  
Recommended minimum installation temperature 0°C  
Maximum operating temperature 70°C  
Short-circuit max. conductor temperature 150°C  
Smoke density IEC 61034  
Gases corrosivity IEC 60754-2  
U.V resistance Yes  
Bending factor when installed 6(xD)  

 TOP
Your selection
Number of cores  
Conductor cross-section  mm²
Nominal outer diameter  mm
Approximate weight  kg/100m
Apply
Reset
Results   10/10
Select all Items Nexans ref. Country ref. Nb. of cores Cross section (mm²) Nom. outer diam. (mm) Approx. weight (kg/100m)
SundaHus EnviroLink 14017098 0454805 3 1.5 9.8 12.7
SundaHus EnviroLink 14017498 0454815 3 2.5 10.5 18.2
SundaHus EnviroLink 14017198 0454905 4 1.5 10.1 15.9
SundaHus EnviroLink 14017598 0454915 4 2.5 11.5 22.1
SundaHus EnviroLink 14017898 0454935 4 6 14.2 39.0
SundaHus EnviroLink 14017298 0455005 5 1.5 10.8 18.3
SundaHus EnviroLink 14017698 0455015 5 2.5 12.4 25.9
SundaHus EnviroLink 14017998 0455035 5 6 15.5 46.9
SundaHus EnviroLink 14017398 0455075 7 1.5 11.8 23.1
SundaHus EnviroLink 14017798 0455085 7 2.5 13.8 34.0