| Product Name |
|
PDF file |
|
AXQJ 1 kV 3-conductor
LV power cables <1 kV/Indoor cables
The cable may be used for fixed installation indoors and outdoors in air, ground and water.
|
|
|
|
AXQJ 1 kV 4-conductor
LV power cables <1 kV/Indoor cables
The cable may be used for fixed installation indoors and outdoors in air, ground and water.
|
|
|
|
EQLQ 450/750 V
Building cables/Building cables
The cable may be used for fixed installation indoors and outdoors. When installing in the ground, the cable shall have an extra protection against mechanical stress. The cable have protection against exposure of UV-light.
|
|
|
|
EQLQ Easy™
Building cables/Building cables
The cable may be used for fixed installation indoors and outdoors. When installing in the ground, the cable shall have an extra protection against mechanical stress. The cable have protection against exposure of UV-light.
|
|
|
|
EQQ Light 300/500 V
Building cables/Building cables
The cable may be used for permanent installation on ladders, directly in walls, concrete, in conduits or ducts. For use indoors and outdoors but not in ground or water. The cable have protection against exposure of UV-light.
|
|
|
|
EXQJ 1 kV
LV power cables <1 kV/Indoor cables
The cable may be used for fixed installation indoors and outdoors in air, ground and water.
|
|
|
|
FQQ 300/500 V
Building cables/Building cables
The cable may be used for permanent installation on ladders, directly in walls, concrete, in conduits or ducts. For use indoors and outdoors but not in ground or water. The cable have protection against exposure of UV-light.
|
|
|
|
FXQJ 1 kV 3-conductor
Building cables/LV cables
The cable may be used for fixed installation indoors and outdoors in air, ground and water.
|
|
|
|
FXQJ EMC 1 kV
Building cables/LV cables
The cable may be used for fixed installation indoors and outdoors in air, ground and water and it's suitable for use in industry locals and other establishments there EMI may cause problems.
|
|
|
|
H07Z1-K (RQ) 450/750 V
Building cables/Flexible cords
The cable may first be used for inside couplings in switch cabinet boxes and similar applications.
|
|
|
|
H07Z1-R (FQ) 450/750 V
Building cables/Building cables
The cable may be used for installation in fixed installed conduit- or duct systems, and also as connecting cable in cupboards and armatures.
|
|
|
|
H07Z1-R (Twisted FQ) 450/750 V
Building cables/Building cables
The cable may be used for installation in fixed installed conduit- or duct systems, and also as connecting cable in cupboards and armatures. The conductors are twisted together to reduce the magnetic field.
|
|
|
|
NOAC-E HFFR 300/500 V (S05Z1A7Z1-F)
Building cables/Specialty LV cables and Flexible cords
The cable may be used indoors in environments that require an extra protection against electrical fields (E-fields), i.e. buildings where electro-hypersensitivity people lives and works. The cable has a restricted field of application. Other allowed applications; like S05Z1Z1-F.
|
|
|
|
S07Z01-R 105GR (FQ 105GR)
Building cables/Flexible cords
Single core wire with rigid stranded copper conductor and insulation of halogenfree flameretardent compound for interior connections and max 105°C operating temperature.
|
|
|