19 inch Fibre optic subrack with fan-out

Products

19 inch Subrack 1U with installation kit 12SM SC/UPC Fan-out

Nexans ref. 48234109-000-00 - Country ref. 5026190

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 44 mm
  • Heightunit: 1 U
  • Number of optical connectors: 12
  • Maximum number of adaptators: 24

 

19 inch Subrack 1U with installation kit 24SM SC/UPC Fan-out

Nexans ref. 48234209-000-00 - Country ref. 5026191

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 44 mm
  • Heightunit: 1 U
  • Number of optical connectors: 24
  • Maximum number of adaptators: 24

 

19 inch Subrack 1U with installation kit 48SM SC/UPC Fan-out

Nexans ref. 48234309-000-00 - Country ref. 5026192

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 44 mm
  • Heightunit: 1 U
  • Number of optical connectors: 48
  • Maximum number of adaptators: 24

 

19 inch Subrack 2U with installation kit 96SM SC/UPC Fan-out

Nexans ref. 48234409-000-00 - Country ref. 5026193

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 88 mm
  • Heightunit: 2 U
  • Number of optical connectors: 96
  • Maximum number of adaptators: 48

 

19 inch Subrack 3U with installation kit 144SM SC/UPC Fan-out

Nexans ref. 48234509-000-00 - Country ref. 5026194

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC
  • Type of secondary protection: 8-fibre ribbon
  • Height: 132 mm
  • Heightunit: 3 U
  • Number of optical connectors: 144
  • Maximum number of adaptators: 72

 

19 inch Subrack 4U with installation kit 192SM SC/UPC Fan-out

Nexans ref. 48234609-000-00 - Country ref. 5026195

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC
  • Type of secondary protection: 8-fibre ribbon
  • Height: 177 mm
  • Heightunit: 4 U
  • Number of optical connectors: 192
  • Maximum number of adaptators: 96

 

19 inch Subrack 1U with installation kit 12SM SC/APC Fan-out

Nexans ref. 48235109-000-00 - Country ref. 5026196

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC/APC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 44 mm
  • Heightunit: 1 U
  • Number of optical connectors: 12
  • Maximum number of adaptators: 24

 

19 inch Subrack 1U with installation kit 24SM SC/APC Fan-out

Nexans ref. 48235209-000-00 - Country ref. 5026197

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC/APC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 44 mm
  • Heightunit: 1 U
  • Number of optical connectors: 24
  • Maximum number of adaptators: 24

 

19 inch Subrack 1U with installation kit 48SM SC/APC Fan-out

Nexans ref. 48235309-000-00 - Country ref. 5026198

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC/APC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 44 mm
  • Heightunit: 1 U
  • Number of optical connectors: 48
  • Maximum number of adaptators: 24

 

19 inch Subrack 2U with installation kit 96SM SC/APC Fan-out

Nexans ref. 48235409-000-00 - Country ref. 5026199

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC/APC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 88 mm
  • Heightunit: 2 U
  • Number of optical connectors: 96
  • Maximum number of adaptators: 48

 

19 inch Subrack 3U with installation kit 144SM SC/APC Fan-out

Nexans ref. 48235509-000-00 - Country ref. 5026200

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC/APC
  • Type of secondary protection: 8-fibre ribbon
  • Height: 132 mm
  • Heightunit: 3 U
  • Number of optical connectors: 144
  • Maximum number of adaptators: 72

 

19 inch Subrack 4U with installation kit 192SM SC/APC Fan-out

Nexans ref. 48235609-000-00 - Country ref. 5026201

  • Packaging: Box (Unit)
  • Type of patching panel: SC Duplex
  • Connector type: SC/APC
  • Type of secondary protection: 8-fibre ribbon
  • Height: 177 mm
  • Heightunit: 4 U
  • Number of optical connectors: 192
  • Maximum number of adaptators: 96

 

19 inch Subrack 1U with installation kit 12SM LC/UPC Fan-out

Nexans ref. 48236109-000-00 - Country ref. 5026202

  • Packaging: Box (Unit)
  • Type of patching panel: LC
  • Connector type: LC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 44 mm
  • Heightunit: 1 U
  • Number of optical connectors: 12
  • Maximum number of adaptators: 3

 

19 inch Subrack 1U with installation kit 24SM LC/UPC Fan-out

Nexans ref. 48236209-000-00 - Country ref. 5026203

  • Packaging: Box (Unit)
  • Type of patching panel: LC
  • Connector type: LC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 44 mm
  • Heightunit: 1 U
  • Number of optical connectors: 24
  • Maximum number of adaptators: 6

 

19 inch Subrack 1U with installation kit 48SM LC/UPC Fan-out

Nexans ref. 48236309-000-00 - Country ref. 5026204

  • Packaging: Box (Unit)
  • Type of patching panel: LC
  • Connector type: LC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 44 mm
  • Heightunit: 1 U
  • Number of optical connectors: 48
  • Maximum number of adaptators: 12

 

19 inch Subrack 1U with installation kit 96SM LC/UPC Fan-out

Nexans ref. 48236409-000-00 - Country ref. 5026205

  • Packaging: Box (Unit)
  • Type of patching panel: LC
  • Connector type: LC
  • Type of secondary protection: 4-fibre ribbon
  • Height: 44 mm
  • Heightunit: 1 U
  • Number of optical connectors: 96
  • Maximum number of adaptators: 24

 

19 inch Subrack 2U with installation kit 144SM LC/UPC Fan-out

Nexans ref. 48236509-000-00 - Country ref. 5026206

  • Packaging: Box (Unit)
  • Type of patching panel: LC
  • Connector type: LC
  • Type of secondary protection: 8-fibre ribbon
  • Height: 88 mm
  • Heightunit: 2 U
  • Number of optical connectors: 144
  • Maximum number of adaptators: 36

 

19 inch Subrack 2U with installation kit 192SM LC/UPC Fan-out

Nexans ref. 48236609-000-00 - Country ref. 5026207

  • Packaging: Box (Unit)
  • Type of patching panel: LC
  • Connector type: LC
  • Type of secondary protection: 8-fibre ribbon
  • Height: 88 mm
  • Heightunit: 2 U
  • Number of optical connectors: 192
  • Maximum number of adaptators: 48

 

19 inch Subrack 3U with installation kit 288SM LC/UPC Fan-out

Nexans ref. 48236709-000-00 - Country ref. 5026208

  • Packaging: Box (Unit)
  • Type of patching panel: LC
  • Connector type: LC
  • Type of secondary protection: 8-fibre ribbon
  • Height: 132 mm
  • Heightunit: 3 U
  • Number of optical connectors: 288
  • Maximum number of adaptators: 72

 

19 inch Subrack 4U with installation kit 384SM LC/UPC Fan-out

Nexans ref. 48236809-000-00 - Country ref. 5026209

  • Packaging: Box (Unit)
  • Type of patching panel: LC
  • Connector type: LC
  • Type of secondary protection: 8-fibre ribbon
  • Height: 177 mm
  • Heightunit: 4 U
  • Number of optical connectors: 384
  • Maximum number of adaptators: 96

 

Description

Description

The fiber optic subrack type 19" is designed for use in 19" system. 19" subrack can be installed in a frame/cabinet with a depth of least 400 mm. Fan-outs and adapters are anclosed with the subrack.

Installation movie

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Cabinet format
19"
Box type
Splicing and patching
Colour
White
Cable entry
From two ways
Fiber optic type
SM

Dimensional characteristics

Dimensional characteristics

Depth
305 mm
Width
485 mm
Apex offset
50 µm
Ferrule outer diameter
2,4999 ± 0,0005 mm
Tolerance of cavity diameter
+1, -0 µm
Concentricity error of cavity
< 1,4 µm
Fibre protrusion
< -0,05 µm
Fibre undercut
> -0,05 µm

Usage characteristics

Usage characteristics

Field of application
Indoor
Storage temperature, range
-40 ... 70 °C
Operating temperature, range
-30 ... 70 °C
Ambient installation temperature, range
-15 ... 40 °C

Resources

Resources

Related products

Fiber optic tools, cleaning products and splice protection

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close